+86-15258555916
[email protected]
The Bitzer low temperature piston parallel unit is a centralized refrigeration solution specifically designed for low-temperature operating conditions, combining system stability, operational flexibility, and long-term reliability. The unit adopts a parallel configuration with multiple piston compressors operating together, enabling staged start-up or combined operation in response to actual cooling load variations. This design allows the system to maintain stable cooling output under different operating conditions. The parallel arrangement demonstrates strong adaptability in low-temperature environments and helps improve operating efficiency under partial-load conditions, making it suitable for frozen storage facilities, low-temperature cold chain warehousing, and related industrial refrigeration applications.
The unit features a comprehensive configuration, including key components such as a liquid receiver, oil separator, oil reservoir, check valves, oil equalizer, and vibration-absorbing pipes. These components support stable distribution of refrigerant and lubricating oil among multiple compressors, enhancing the coordinated operation of the parallel system. In addition, the unit is equipped with pressure controllers and an electrical control cabinet for centralized monitoring and management of operating conditions, improving overall operational safety. The modular, combinable frame design also provides greater flexibility for on-site installation and future system expansion.
Equipment Parameters Introduction
Detail Display
Contact Us
Equipment Parameters Introduction
| Unit Model | Com.Model |
Com, Cuartity |
Condensing temp. (℃) |
Evaporation Temp. (℃) | Reservoir (L) |
Supply pipe (mm) |
Suction pipe (mm) |
Gas Outiet pipe (mm) |
liquid inletpipe (mm) |
Dimension(mm) (LxW×H) |
|||||||||
| -20 | -25 | -30 | -35 | -40 | |||||||||||||||
| Coling Capacity/Power Input(kw) | |||||||||||||||||||
| LXPL-BBF2 -18L |
4TES-9 (9HP) |
2 | 35 | 30.1 | 12.3 | 23.3 | 10.9 | 19.7 | 10.0 | 16.3 | 8.4 | 8.8 | 6.7 | 40 | Φ22 | Φ54 | Φ35 | Φ28 | 2500×1000×1850 |
| 40 | 28.0 | 12.9 | 21.4 | 11.3 | 18.4 | 10.7 | 14.3 | 8.7 | 7.7 | 7.0 | |||||||||
| 45 | 25.7 | 13.3 | 19.9 | 11.9 | 16.7 | 11.1 | 13.2 | 9.5 | 6.5 | 7.1 | |||||||||
| LXPL-BBF3 -27L |
3 | 35 | 45.2 | 18.5 | 34.9 | 16.4 | 29.5 | 15.1 | 25.4 | 14.2 | 13.2 | 10.3 | 60 | Φ28 | Φ54 | Φ42 | Φ35 | 3150×1000×1850 | |
| 40 | 42.0 | 19.3 | 32.2 | 16.9 | 27.7 | 16.1 | 20.3 | 12.3 | 11.5 | 10.5 | |||||||||
| 45 | 38.8 | 20.0 | 29.9 | 17.9 | 25.1 | 16.5 | 15.4 | 13.2 | 9.8 | 10.6 | |||||||||
| LXPL-BBF4 -36L |
4 | 35 | 60.3 | 24.6 | 46.6 | 21.8 | 39.3 | 20.1 | 25.7 | 15.4 | 14.6 | 13.7 | 60 | Φ28 | Φ76 | Φ45 | Φ35 | 3800×1000×1850 | |
| 40 | 56.0 | 25.7 | 42.9 | 22.5 | 36.8 | 21.4 | 25.7 | 15.9 | 15.3 | 14.1 | |||||||||
| 45 | 51.7 | 26.7 | 39.8 | 23.8 | 33.5 | 22.1 | 24.7 | 18.2 | 13.1 | 14.2 | |||||||||
| LXPL-BBF2 -24L |
4PES-12 (12HP) |
2 | 35 | 32.9 | 13.7 | 24.9 | 12.1 | 20.8 | 11.1 | 17.4 | 9.3 | 10.1 | 7.9 | 50 | Φ22 | Φ54 | Φ35 | Φ28 | 2500×1000×1850 |
| 40 | 30.2 | 14.2 | 22.7 | 12.4 | 18.8 | 11.2 | 13.6 | 10.1 | 8.8 | 8.0 | |||||||||
| 45 | 27.6 | 14.6 | 20.5 | 12.6 | 16.8 | 11.3 | 13.2 | 9.1 | 7.6 | 8.8 | |||||||||
| LXPL-BBF3 -36L |
3 | 35 | 49.3 | 20.6 | 37.4 | 18.0 | 31.2 | 16.6 | 25.4 | 13.2 | 15.1 | 11.9 | 80 | Φ27 | Φ66 | Φ35 | Φ28 | 3150×1000×1850 | |
| 40 | 45.3 | 21.3 | 34.1 | 18.5 | 28.2 | 16.8 | 21.7 | 15.4 | 13.3 | 21.1 | |||||||||
| 45 | 41.3 | 21.9 | 30.7 | 18.8 | 25.2 | 17.1 | 18.9 | 15.4 | 11.4 | 12.1 | |||||||||
| LXPL-BBF4 -48L |
4 | 35 | 65.7 | 27.4 | 49.8 | 24.1 | 41.6 | 22.1 | 35.2 | 18.2 | 20.1 | 10.6 | 100 | Φ28 | Φ66 | Φ35 | Φ35 | 3800×1000×1850 | |
| 40 | 60.4 | 28.4 | 45.4 | 24.7 | 37.6 | 22.4 | 37.6 | 22.4 | 17.6 | 16.0 | |||||||||
| 45 | 55.1 | 29.5 | 41.0 | 25.2 | 26.3 | 22.7 | 26.3 | 22.7 | 15.2 | 16.2 | |||||||||
| LXPL-BBF2 -28L |
4NES-14 (14HP) |
2 | 35 | 40.6 | 16.5 | 31.3 | 14.6 | 24.9 | 13.4 | 24.9 | 13.4 | 11.6 | 9.3 | 60 | Φ22 | Φ54 | Φ35 | Φ28 | 2500×1000×1850 |
| 40 | 37.6 | 17.2 | 28.7 | 15.0 | 22.7 | 14.1 | 22.7 | 14.1 | 10.3 | 9.5 | |||||||||
| 45 | 34.7 | 17.8 | 27.0 | 15.8 | 24.8 | 14.5 | 24.8 | 14.5 | 8.8 | 9.6 | |||||||||
| LXPL-BBF3 -42L |
3 | 35 | 60.9 | 24.7 | 46.9 | 21.8 | 22.6 | 20.0 | 22.6 | 20.0 | 17.5 | 14.0 | 100 | Φ28 | Φ54 | Φ42 | Φ35 | 3150×1000×1850 | |
| 40 | 56.4 | 25.8 | 43.1 | 22.5 | 37.3 | 21.2 | 37.3 | 21.2 | 15.5 | 14.2 | |||||||||
| 45 | 52.0 | 26.7 | 40.5 | 23.6 | 34.0 | 21.7 | 34.0 | 21.7 | 13.3 | 14.4 | |||||||||
| LXPL-BBF4 -56L |
4 | 35 | 81.2 | 33.0 | 62.5 | 29.1 | 52.7 | 26.7 | 52.7 | 26.7 | 23.3 | 18.6 | 150 | Φ28 | Φ76 | Φ42 | Φ35 | 3800×1000×1850 | |
| 40 | 75.2 | 34.4 | 57.4 | 30.0 | 49.7 | 28.2 | 49.7 | 28.2 | 20.6 | 19.0 | |||||||||
| 45 | 69.4 | 35.6 | 54.0 | 31.5 | 45.3 | 28.9 | 45.3 | 28.9 | 17.8 | 19.2 | |||||||||
| LXPL-BBF2 -36L |
4HE-18 (18HP) |
2 | 35 | 54.0 | 24.9 | 42.2 | 19.5 | 35.8 | 18.1 | 35.8 | 18.1 | 14.0 | 11.9 | 60 | Φ22 | Φ76 | Φ35 | Φ28 | 2500×1000×1850 |
| 40 | 50.2 | 22.8 | 38.9 | 20.2 | 31.3 | 18.4 | 31.3 | 18.4 | 12.3 | 11.8 | |||||||||
| 45 | 46.4 | 23.6 | 34.3 | 20.8 | 28.7 | 19.0 | 28.7 | 19.0 | 10.7 | 11.7 | |||||||||
| LXPL-BBF3 -54L |
3 | 35 | 81.0 | 32.8 | 63.3 | 29.3 | 53.7 | 27.2 | 53.7 | 27.2 | 80.1 | 17.8 | 100 | Φ28 | Φ76 | Φ42 | Φ35 | 3150×1000×1850 | |
| 40 | 75.3 | 34.2 | 58.2 | 30.3 | 47.0 | 27.7 | 47.0 | 27.7 | 75.0 | 17.7 | |||||||||
| 45 | 69.6 | 35.3 | 52.5 | 31.3 | 43.0 | 28.6 | 43.0 | 28.6 | 67.2 | 17.5 | |||||||||
| LXPL-BBF4 -72L |
4 | 35 | 108.0 | 43.7 | 84.4 | 39.0 | 71.7 | 36.2 | 71.7 | 36.2 | 106.8 | 23.8 | 150 | Φ28 | Φ89 | Φ54 | Φ35 | 3800×1000×1850 | |
| 40 | 100.4 | 45.6 | 77.7 | 40.4 | 62.6 | 36.9 | 62.6 | 36.9 | 100.0 | 23.6 | |||||||||
| 45 | 92.8 | 47.1 | 68.7 | 41.7 | 57.3 | 38.2 | 57.3 | 38.2 | 89.6 | 23.4 | |||||||||
| Unit Model | Com.Model | Com. Curtity |
Condensing temp. (℃) |
Evaporation Temp. (℃) | Reservoir (L) |
Supply pipe (mm) |
Suction pipe (mm) |
Gas Outiet pipe (mm) |
liquid inletpipe (mm) |
Dimension(mm) (L×W×H) |
|||||||||
| -20 | -25 | -30 | -35 | -40 | |||||||||||||||
| Cooling Capacity/Power Input(kw) | |||||||||||||||||||
| LXPL-BBF2 -46L |
4GE-23 (23HP) |
2 | 35 | 64.4 | 26.2 | 50.6 | 23.6 | 43.2 | 21.9 | 16.4 | 14.3 | 16.4 | 14.3 | 60 | Φ28 | Φ76 | Φ42 | Φ35 | 2500×1000×1850 |
| 40 | 60.0 | 27.5 | 47.0 | 24.5 | 36.3 | 21.9 | 14.4 | 14.2 | 14.4 | 14.2 | |||||||||
| 45 | 56.0 | 28.6 | 39.8 | 24.9 | 33.3 | 22.9 | 12.6 | 14.1 | 12.6 | 14.1 | |||||||||
| LXPL-BBF3 -69L |
3 | 35 | 96.6 | 39.3 | 75.9 | 35.3 | 64.8 | 32.9 | 24.6 | 21.4 | 24.6 | 21.4 | 100 | Φ35 | Φ89 | Φ54 | Φ42 | 3150×1000×1850 | |
| 40 | 90.0 | 41.2 | 70.5 | 36.8 | 54.5 | 32.9 | 21.5 | 21.4 | 21.5 | 21.4 | |||||||||
| 45 | 84.0 | 43.0 | 59.8 | 37.5 | 50.0 | 34.4 | 18.8 | 21.3 | 18.8 | 21.3 | |||||||||
| LXPL-BBF4 -92L |
4 | 35 | 128.8 | 52.4 | 101.2 | 47.1 | 86.4 | 43.9 | 32.8 | 28.6 | 32.8 | 28.6 | 150 | Φ35 | Φ89 | Φ54 | Φ42 | 3800×1000×1850 | |
| 40 | 120.0 | 55.0 | 94.0 | 49.1 | 72.6 | 43.9 | 28.7 | 28.6 | 28.7 | 28.6 | |||||||||
| 45 | 112.0 | 53.7 | 79.7 | 49.9 | 66.7 | 45.9 | 25.1 | 28.4 | 25.1 | 28.4 | |||||||||
| LXPL-BBF2 -50L |
6JE-25 (25HP) |
2 | 35 | 69.6 | 28.0 | 54.2 | 25.0 | 46.0 | 23.2 | 18.2 | 15.4 | 18.2 | 15.4 | 100 | Φ28 | Φ67 | Φ42 | Φ35 | 2500×1000×1850 |
| 40 | 64.6 | 29.1 | 50.0 | 25.8 | 40.6 | 23.8 | 15.9 | 15.2 | 15.9 | 15.2 | |||||||||
| 45 | 59.8 | 30.1 | 44.4 | 26.9 | 37.1 | 24.6 | 13.9 | 15.1 | 13.9 | 15.1 | |||||||||
| LXPL-BBF3 -75L |
3 | 35 | 104.4 | 41.9 | 81.3 | 37.5 | 69.0 | 34.8 | 27.2 | 23.1 | 27.2 | 23.1 | 150 | Φ28 | Φ67 | Φ42 | Φ35 | 3150×1000×1850 | |
| 40 | 96.9 | 43.7 | 75.0 | 38.7 | 60.9 | 35.7 | 23.8 | 22.9 | 23.8 | 22.9 | |||||||||
| 45 | 89.7 | 45.1 | 66.6 | 40.4 | 55.7 | 36.9 | 20.9 | 22.6 | 20.9 | 22.6 | |||||||||
| LXPL-BBF4 -100L |
4 | 35 | 139.2 | 55.9 | 108.4 | 50.0 | 92.0 | 46.4 | 36.3 | 30.8 | 36.3 | 30.8 | 200 | Φ35 | Φ76 | Φ54 | Φ42 | 3800×1000×1850 | |
| 40 | 129.2 | 58.2 | 100.0 | 51.6 | 81.2 | 47.6 | 31.8 | 30.5 | 31.8 | 30.5 | |||||||||
| 45 | 119.6 | 60.2 | 88.8 | 53.8 | 74.2 | 49.2 | 27.8 | 30.1 | 27.8 | 30.1 | |||||||||
| LXPL-BBF2 -56L |
6HE-28 (28HP) |
2 | 35 | 82.6 | 33.3 | 64.6 | 29.9 | 55.2 | 27.8 | 21.1 | 17.9 | 21.1 | 17.9 | 100 | Φ28 | Φ76 | Φ42 | Φ35 | 2500×1000×1850 |
| 40 | 77.0 | 34.9 | 5.98 | 31.0 | 47.0 | 27.6 | 18.4 | 17.7 | 18.4 | 17.7 | |||||||||
| 45 | 71.4 | 36.2 | 51.6 | 31.2 | 43.0 | 28.5 | 16.1 | 17.5 | 16.1 | 17.5 | |||||||||
| LXPL-BBF3 -84L |
3 | 35 | 123.9 | 50.0 | 96.9 | 44.9 | 82.8 | 41.7 | 31.6 | 26.9 | 31.6 | 26.9 | 150 | Φ35 | Φ89 | Φ54 | Φ42 | 3150×1000×1850 | |
| 40 | 115.5 | 52.3 | 89.7 | 46.5 | 70.5 | 41.5 | 27.7 | 26.6 | 27.7 | 26.6 | |||||||||
| 45 | 101.7 | 54.3 | 77.4 | 46.8 | 64.5 | 42.8 | 24.2 | 26.2 | 24.2 | 26.2 | |||||||||
| LXPL-BBF4 -112L |
4 | 35 | 165.2 | 66.7 | 129.2 | 59.8 | 110.4 | 55.6 | 42.2 | 35.8 | 42.2 | 35.8 | 2000 | Φ35 | Φ108 | Φ54 | Φ42 | 3800×1000×2000 | |
| 40 | 154.0 | 69.7 | 119.6 | 62.0 | 94.0 | 55.3 | 36.9 | 35.4 | 36.9 | 35.4 | |||||||||
| 45 | 142.8 | 72.4 | 103.2 | 62.4 | 86.0 | 57.1 | 32.2 | 34.9 | 32.2 | 34.9 | |||||||||
| LXPL-BBF2 -68L |
6JE-34 (34HP) |
2 | 35 | 95.4 | 38.7 | 74.6 | 34.7 | 63.8 | 32.3 | 24.6 | 21.4 | 24.6 | 21.4 | 1500 | Φ35 | Φ89 | Φ54 | Φ42 | 2500×1000×1850 |
| 40 | 88.8 | 40.6 | 69.2 | 36.1 | 54.6 | 32.9 | 21.5 | 21.3 | 21.5 | 21.3 | |||||||||
| 45 | 82.6 | 42.2 | 59.8 | 37.4 | 50.0 | 34.4 | 18.8 | 21.3 | 18.8 | 21.3 | |||||||||
| LXPL-BBF3 -102L |
3 | 35 | 143.1 | 58.1 | 111.9 | 52.1 | 95.7 | 48.4 | 36.9 | 32.1 | 36.9 | 32.1 | 200 | Φ35 | Φ108 | Φ54 | Φ42 | 3150×1000×1850 | |
| 40 | 133.2 | 60.9 | 103.8 | 54.2 | 81.9 | 49.4 | 32.3 | 32.0 | 32.3 | 32.0 | |||||||||
| 45 | 123.9 | 63.3 | 89.7 | 56.2 | 75.0 | 51.5 | 28.2 | 31.9 | 28.2 | 31.9 | |||||||||
| LXPL-BBF4 -136L |
4 | 35 | 190.8 | 77.5 | 149.2 | 69.4 | 127.6 | 64.5 | 49.1 | 42.8 | 49.1 | 42.8 | 300 | Φ42 | Φ108 | Φ67 | Φ54 | 3800×1000×2000 | |
| 40 | 177.6 | 81.2 | 138.4 | 72.2 | 109.2 | 65.8 | 43.1 | 42.8 | 43.1 | 42.8 | |||||||||
| 45 | 165.2 | 84.4 | 119.6 | 74.8 | 100.0 | 68.7 | 37.6 | 42.5 | 37.6 | 42.5 | |||||||||
Detail Display

Contact Us
Complete Condenser Selection Guide: Choose the Right Condenser for Industrial & HVAC Systems A condenser is a core heat transfer component widely used in HVAC systems, industrial refrigeration, chemical processing, power generation, and...
READ MORECold storage engineering suppliers' OEM customization guide As the demand for segmented markets in the overseas cold chain industry increases, many cold storage engineering suppliers and traders aim to create their own equipment brands thro...
READ MORELooking for an affordable, energy-saving alternative to air conditioners for residential, commercial, or industrial cooling? Evaporative air coolers have become the top choice for users worldwide, thanks to their low power consumption, eco...
READ MORE