+86-15258555916
[email protected]
Total cooling load = Storage volume (m³) × Unit load
1 horsepower (HP) ≈ 2kW cooling capacity at low temperature
Compressor capacity = Total load × 1.1~1.2 (safety margin)
HP conversion: Compressor capacity ÷ 2
Simple HP reference
Match heat exchange area by compressor HP
Small warehouse aluminum pipe: Volume × 0.45㎡/m³
Select air cooler model directly by HP
Water-cooled & evaporative condenser: Area is 1/15~1/20 of air-cooled type
30-second Matching Steps
Practical Example
100m³ low temp storage (-18°C)
Key Notes
While searching for a evaporator and condenser manufacturer, Lanxi Refrigeration is certainly worth ...